the endress hauser tuning fork limit detection ftl50h-aee2ac2g6a is an integrated tuning fork limit switch, suitable for liquid medium measurement, especially in the fields of food and life sciences
application field
· the liquiphant ftl50h tuning fork limit switch can be used in hazardous areas. it has passed multiple international certifications and obtained hygiene certifications such as 3-a, ehedg, and asme bpe. it is particularly suitable for the fields of food and life sciences. the functional safety level of ftl50h reaches sil2/sil3, with stable measurement values that are not affected by medium flow, disturbance, bubbles, foam, vibration, solid content or adhesion.
· the limit switch with a fully welded housing design is suitable for liquid measurement
· process connection: threaded, flange and sanitary connection (clamp, milk joint, aseptic type, drd, sms, varivent)
· temperature: -50... 150°c (-58 ... 302°f)
· pressure: -1... 64bar (-14.5...) 928psi)
· sensor material: 316l
· international explosion-proof certification, whg overflow protection, sil, sanitary certification, ship class certification
advantage
· it can be used in safety systems with functional safety level requirements of sil2/sil3 and complies with the iec 61508/iec 61511-1 standard
· multiple process connections are available for selection
· equipped with a variety of electronic plug-in types, such as namur, relays, semiconductor thyristors, and pfm signal outputs, it enables connection with various process control systems
· the profibus pa communication protocol can also be selected
· no calibration required: quick and economical device startup mode
· there are no mechanical moving parts, no maintenance required, no wear and tear, and a long service life. it can monitor the damage of the fork body to ensure normal function
· fda-certified materials (pfa edlon)
· liquid limit detection
|
measurement principle |
liquid tuning fork |
|
characteristics/applications |
modular integral welded housing |
|
characteristics |
foam detection |
|
power supply/communication |
profibus pa |
|
ambient temperature |
-50... 70 °c |
|
process temperature |
-50... 150 °c |
|
process pressure (absolute pressure)/maximum overpressure limit value |
vacuum...64 bar |
|
minimum medium density |
0.5g/cm³(optional 0.4g/cm³) |
|
main liquid-contact components |
316l |
|
process connection |
thread: |
|
hygienic process connection |
tri-clamp iso2852 clamp |
|
communication |
profibus pa |
|
certificates and certifications |
atex、fm、csa、csa c/us、iec ex、tiis、inmetro、nepsi |
|
security certification |
overflow protection whg |
|
design certification |
en 10204-3.1 |
|
hygienic certification |
coc asme-bpe |
|
ship classification certification |
gl、abs |
|